Resource Library

Why “White Coils” are a “Red Flag”

The importance of preventing the ingress of air during global vacuum pressure impregnation of form-coil windings

  • September 2022
  • Number of views: 3243
  • Article rating: 3.3
Article

The goal of vacuum pressure impregnation is complete saturation of a winding with insulating resin. As resin penetrates the insulating materials, it causes them to darken. If some insulation is a lighter shade, the coil or jumper is not fully saturated. The winding is not properly protected, and if the problem is not addressed, it is likely to cause premature failure of the unit. This could result in costly warranty work, or at a minimum, will be a failure to provide your customers with the quality they expect and deserve.

Porqué las "Bobinas Bancas" son una "Señal de Alarma"

La importancia de prevenir el ingreso de aire durante la impregnación global por vacío y presión de los bobinados preformados

  • September 2022
  • Number of views: 2410
  • Article rating: No rating
Article

El objetivo de la impregnación por vacío y presión (VPI) es saturar completamente un devanado con resina aislante. A medida que la resina penetra en los materiales aislantes, los oscurece y al drenar la resina VPI del devanado, todo el aislamiento de las cabezas queda oscuro en un tono uniforme. El aislamiento de la conexión también debe quedar oscuro de forma pareja. Si algún aislamiento muestra un tono más claro, la bobina o el puente no han quedado completamente saturados y el devanado no está debidamente protegido. Si no se soluciona el problema, es probable que esto provoque un fallo prematuro en el equipo. Esto podría generar una garantía costosa o, como mínimo, la reparación no brindará a sus clientes la calidad que esperan y merecen.

Best AC Rewind Practices

  • February 2021
  • Number of views: 16160
  • Article rating: 4.0
FREE for Members of EASA
Webinar recording

This webinar recording shares some of the “best practice” rewind methods used by (and learned from) EASA service centers around the world: connection recognition, best insulating materials, wire choices and tips to save time and effort.

AC Stator Form Coil Data Sheet

  • February 2021
  • Number of views: 8922
  • Article rating: 3.5
Form/Worksheet

This handy form provides fields to record all of the details needed to document and/or order replacement coils for an AC form-wound machine. The form also includes detailed descriptions/definitions of the data to be recorded in each field. 

Getting the most from power factor tip-up testing

  • April 2017
  • Number of views: 18378
  • Article rating: 1.0
Article

The power factor tip-up test is commonly used as a quality measurement for new coils and windings manufactured for AC motors and generators rated 6 kV and higher. It can also be useful in the rewind shop to verify the quality of a newly-installed coil system including the effectiveness of VPI processing.

Aprovechando al máximo la prueba de factor de potencia tip-up

  • April 2017
  • Number of views: 17145
  • Article rating: 5.0
Article

 

La prueba de volcado del factor de potencia se usa comúnmente como una medida de calidad para bobinas y devanados nuevos fabricados para motores de CA y generadores con clasificación de 6 kV y más. También puede ser útil en el taller de rebobinado para verificar la calidad de un sistema de bobina recién instalado, incluida la efectividad del procesamiento de VPI.

Coil pitch and the search for the perfect sine wave

  • January 2004
  • Number of views: 4049
  • Article rating: No rating
Article

This started as an article to explain those cases where a 2-pole winding concentric-to-lap conversion will not run. The cause has to do with the coil pitch selected and slot spatial harmonics. These harmonics have a harmful effect on motor performance. The key is avoiding certain coil pitches, and the "problem" 2-pole pitch depends on the number of slots and the coil pitch. To make the article more useful, it includes tables to identify "preferred" coil pitches for2-pole, 3-phase windings, as well as those that should be avoided.

Getting The Most From Your Electric Motors

Getting The Most From Your Electric Motors - coverThis 40-page booklet provides great advice for obtaining the longest, most efficient and cost-effective operation from general and definite purpose electric motors.

This booklet covers topics such as:

  • Installation, startup and baseline information
  • Operational monitoring and maintenance
  • Motor and baseline installation data
  • How to read a motor nameplate
  • Motor storage recommendations

LEARN MORE AND DOWNLOAD MÁS INFORMACIÓN Y DESCARGAR BUY PRINTED COPIES

READ MORE ABOUT THE FEATURES AND BENEFITS

EASA/AEMT Rewind Study

EASA Rewind Study cover

The Effect of Repair/Rewinding on Premium Efficiency/IE3 Motors
Tests prove Premium Efficiency/IE3 Motors can be rewound without degrading efficiency.

DOWNLOAD THE FULL RESULTS

ANSI/EASA AR100-2020

ANSI/EASA AR100-2015 cover

Recommended Practice for the Repair of Rotating Electrical Apparatus
This is a must-have guide to the repair of rotating electrical machines. Its purpose is to establish recommended practices in each step of the rotating electrical apparatus rewinding and rebuilding processes.

DOWNLOAD - ENGLISH

DESCARGAR - ESPAÑOL

EASA Technical Manual

EASA Technical Manual cover

Revised May 2024
The EASA Technical Manual is the association's definitive and most complete publication. It's available FREE to members in an online format. Members can also download PDFs of the entire manual or individual sections.

VIEW & DOWNLOAD