Controlled Environments and Cleanrooms Prevent Contamination in Service Centers

  • April 2022
  • Number of views: 3891
  • Article rating: No rating
Article

This article explores the distinction between a controlled environment and a cleanroom, the requirements for both, and provides details to help you determine if you want to add a controlled environment or a cleanroom to your facility.

Los Ambientes Controlados y los Cuartos Limpios Previenen la Contaminación en los Centros de Servicio

  • April 2022
  • Number of views: 3538
  • Article rating: No rating
Article

Aquí, exploraremos la diferencia entre un ambiente controlado y un cuarto limpio, los requisitos para ambos y proporcionaremos detalles para ayudarle a determinar si quiere añadir a sus instalaciones un ambiente controlado o un cuarto limpio.

Rewind 2021

Recordings and Handouts from the 2021 EASA Convention - Fort Worth, TX

  • June 2021
  • Number of views: 10347
  • Article rating: 5.0
Convention presentation

Revisit EASA's 2021 Convention & Solutions Expo by buying access to recordings of the general sessions and education events streamed from EASA's website! These recordings provide just over 22 hours of training. Downloadable PDFs of slides and technical papers are included!

The Care & Use of Micrometers

  • June 2021
  • Number of views: 5369
  • Article rating: 5.0
Article

The importance of precise and accurate measurements is more critical today than ever. Our customers are increasingly demanding of best possible practices and outcomes when having their machinery serviced and repaired. The ideas and information presented here are applicable to other mechanical measuring devices such as inside micrometers, calipers, protractors, levels, depth gauges and such.

El cuidado y Uso de los Micrómetros

  • June 2021
  • Number of views: 5368
  • Article rating: No rating
Article

En este artículo trataremos los micrómetros exteriores. Sin embargo, las ideas y la información aplican a otros dispositivos de medición, tales como: Micrómetros de interiores, calibradores, transportadores, niveles, galgas de profundidad, etc.

Encourage (Proper) Use of Mobile Devices in the Service Center

  • April 2021
  • Number of views: 6958
  • Article rating: 1.0
Article

There are plenty of generic mobile device policies floating around the web. Sadly, many of them focus heavily and narrowly on the disadvantages of team members having personal devices at their workstations. Too often organizations take the path of excluding mobile devices from the work area because it’s easy rather than reaping the benefits they offer.

Fomente el Uso (Adecuado) de Dispositivos Móviles en el Centro de Servicio

  • April 2021
  • Number of views: 6903
  • Article rating: No rating
Article

Existen muchas políticas genéricas sobre el uso de los dispositivos móviles flotando en internet. Dependiendo del entorno particular y de las herramientas utilizadas, es razonable y responsable evaluar los riesgos potenciales para la seguridad y la protección. Sin embargo, con mucha frecuencia, las organizaciones toman el camino de excluir los dispositivos móviles del área de trabajo porque es una medida fácil, en lugar de aprovechar los beneficios que ofrecen.

Important Considerations for Accommodating Pump Repair in Your Service Center

  • June 2020
  • Number of views: 6633
  • Article rating: No rating
Article

It happens to just about every EASA service center. A machine shows up for repair; it has leads, and there’s a motor, but the machine is a pump. Most often, it’s a close-coupled pump or a submersible pump. If your response is, “We don’t work on those here,” because you’re thinking, “We don’t know anything about repairing pumps,” you may be turning your back on some very profitable work.

Consideraciones Importantes Para Acondicionar la Reparación de Bombas en su Centro de Servicio

  • June 2020
  • Number of views: 6471
  • Article rating: No rating
Article

Esto sucede en casi todos los centros de servicio de EASA, aparece una máquina para reparación, con cables y un motor, pero es una bomba. A menudo es una bomba sumergible o de acoplamiento cerrado. Si su respuesta es: “Aquí no reparamos estos equipos” y está pensando: “Nosotros no sabemos nada sobre reparación de bombas” puede que le esté dando la espalda a un trabajo muy rentable.

End Users Offer Perspective on Internet-Enabled Condition Monitoring

  • January 2020
  • Number of views: 6684
  • Article rating: No rating
Article

In March of 2019, EASA conducted an in-depth survey to better understand how end users decide between repairing or replacing electric motors and to identify electric motor repair/replacement trends. Internet-enabled condition monitoring has been a hot topic recently and, as a result, questions related to this were added to the list of survey questions. The survey returned some very interesting results about internet-enabled condition monitoring.

Getting The Most From Your Electric Motors

Getting The Most From Your Electric Motors - coverThis 40-page booklet provides great advice for obtaining the longest, most efficient and cost-effective operation from general and definite purpose electric motors.

This booklet covers topics such as:

  • Installation, startup and baseline information
  • Operational monitoring and maintenance
  • Motor and baseline installation data
  • How to read a motor nameplate
  • Motor storage recommendations

LEARN MORE AND DOWNLOAD MÁS INFORMACIÓN Y DESCARGAR BUY PRINTED COPIES

READ MORE ABOUT THE FEATURES AND BENEFITS

EASA/AEMT Rewind Study

EASA Rewind Study cover

The Effect of Repair/Rewinding on Premium Efficiency/IE3 Motors
Tests prove Premium Efficiency/IE3 Motors can be rewound without degrading efficiency.

DOWNLOAD THE FULL RESULTS

ANSI/EASA AR100-2020

ANSI/EASA AR100-2015 cover

Recommended Practice for the Repair of Rotating Electrical Apparatus
This is a must-have guide to the repair of rotating electrical machines. Its purpose is to establish recommended practices in each step of the rotating electrical apparatus rewinding and rebuilding processes.

DOWNLOAD - ENGLISH

DESCARGAR - ESPAÑOL

EASA Technical Manual

EASA Technical Manual cover

Revised September 2022
The EASA Technical Manual is the association's definitive and most complete publication. It's available FREE to members in an online format. Members can also download PDFs of the entire manual or individual sections.

VIEW & DOWNLOAD