﻿<?xml version="1.0" encoding="utf-8"?><!--RSS Genrated: Wed, 22 Apr 2026 18:11:05 GMT--><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:ev="http://purl.org/rss/1.0/modules/event/"><channel><title>EASA | The Electro•Mechanical Authority - Testing</title><link>https://easa.com:443/resources/resource-library/rss/category/2680/testing</link><atom:link href="https://easa.com:443/resources/resource-library/rss/category/2680/testing" rel="self" type="application/rss+xml" /><description>RSS document</description><item><dc:creator><![CDATA[William]]></dc:creator><title><![CDATA[Vibration - Coast-Down Analysis]]></title><link>https://easa.com/resources/resource-library/vibration-coast-down-analysis-1</link><description><![CDATA[    Gene Vogel 
EASA Pump & Vibration Specialist 

 Spectrum analysis is the primary tool for analyzing vibration problems. Yet, a lot of useful information can be acquired by tracking the ...]]></description><pubDate>Wed, 11 Feb 2026 18:00:00 GMT</pubDate><guid>https://easa.com/resources/resource-library/vibration-coast-down-analysis-1</guid><dc:identifier><![CDATA[254e0687-d427-4b59-9b7b-a507e4dcb9f6-3909]]></dc:identifier></item><item><dc:creator><![CDATA[William]]></dc:creator><title><![CDATA[Quick Checks for Resonance]]></title><link>https://easa.com/resources/resource-library/quick-checks-for-resonance</link><description><![CDATA[ Gene Vogel 
EASA Pump & Vibration Specialist  

 When high vibration occurs on a machine at a single frequency and in only one plane, the cause is often a resonant condition. All machines have ...]]></description><pubDate>Sun, 01 Feb 2026 06:05:00 GMT</pubDate><guid>https://easa.com/resources/resource-library/quick-checks-for-resonance</guid><dc:identifier><![CDATA[254e0687-d427-4b59-9b7b-a507e4dcb9f6-3901]]></dc:identifier></item><item><dc:creator><![CDATA[William]]></dc:creator><title><![CDATA[Comprobaciones rápidas de resonancia]]></title><link>https://easa.com/resources/resource-library/comprobaciones-r225pidas-de-resonancia</link><description><![CDATA[ Gene Vogel 
Especialista de Bombas & Vibraciones de EASA  

 Cuando se produce una vibración elevada en una máquina a una sola frecuencia y en un solo plano, la causa suele ser una condición de ...]]></description><pubDate>Sun, 01 Feb 2026 06:05:00 GMT</pubDate><guid>https://easa.com/resources/resource-library/comprobaciones-r225pidas-de-resonancia</guid><dc:identifier><![CDATA[254e0687-d427-4b59-9b7b-a507e4dcb9f6-3902]]></dc:identifier></item><item><dc:creator><![CDATA[William]]></dc:creator><title><![CDATA[Tests to Ensure Proper DC Machine Performance]]></title><link>https://easa.com/resources/resource-library/tests-to-ensure-proper-dc-machine-performance</link><description><![CDATA[ Chuck Yung 
EASA Senior Technical Support Specialist  

  This is an update to articles I wrote starting in 1999 and subsequently used as part of the foundation for “Fundamentals of DC: Operation ...]]></description><pubDate>Thu, 01 Jan 2026 06:02:00 GMT</pubDate><guid>https://easa.com/resources/resource-library/tests-to-ensure-proper-dc-machine-performance</guid><dc:identifier><![CDATA[254e0687-d427-4b59-9b7b-a507e4dcb9f6-3879]]></dc:identifier></item><item><dc:creator><![CDATA[William]]></dc:creator><title><![CDATA[Pruebas para asegurar el correcto funcionamiento de las máquinas de CC]]></title><link>https://easa.com/resources/resource-library/pruebas-para-asegurar-el-correcto-funcionamiento-de-las-maquinas-de-cc</link><description><![CDATA[ Chuck Yung 
Especialista Sénior de Soporte Técnico de EASA 

  Esta es una actualización de los artícu-los que escribí a comienzos de 1999 y que posteriormente sirvieron como base del libro ...]]></description><pubDate>Thu, 01 Jan 2026 06:00:00 GMT</pubDate><guid>https://easa.com/resources/resource-library/pruebas-para-asegurar-el-correcto-funcionamiento-de-las-maquinas-de-cc</guid><dc:identifier><![CDATA[254e0687-d427-4b59-9b7b-a507e4dcb9f6-3881]]></dc:identifier></item><item><dc:creator><![CDATA[William]]></dc:creator><title><![CDATA[Variable Speed Drive for Pump Testing]]></title><link>https://easa.com/resources/resource-library/variable-speed-drive-for-pump-testing</link><description><![CDATA[ By Gene Vogel 
EASA Pump & Vibration Specialist 

 Many EASA service centers have installed facilities for operational testing of pumps. Equipping a pump test facility for variable speed ...]]></description><pubDate>Sat, 01 Nov 2025 05:05:00 GMT</pubDate><guid>https://easa.com/resources/resource-library/variable-speed-drive-for-pump-testing</guid><dc:identifier><![CDATA[254e0687-d427-4b59-9b7b-a507e4dcb9f6-3854]]></dc:identifier></item><item><dc:creator><![CDATA[William]]></dc:creator><title><![CDATA[Variador de velocidad para pruebas de bombas]]></title><link>https://easa.com/resources/resource-library/variador-de-velocidad-para-pruebas-de-bombas</link><description><![CDATA[ Gene Vogel 
Especialista de Bombas & Vibraciones de EASA  

 Muchos centros de servicio de EASA han adecuado sus instalaciones para realizar pruebas dinámicas de bombas. Emplear velocidad ...]]></description><pubDate>Sat, 01 Nov 2025 05:05:00 GMT</pubDate><guid>https://easa.com/resources/resource-library/variador-de-velocidad-para-pruebas-de-bombas</guid><dc:identifier><![CDATA[254e0687-d427-4b59-9b7b-a507e4dcb9f6-3855]]></dc:identifier></item><item><dc:creator><![CDATA[William]]></dc:creator><title><![CDATA[Seeing the Invisible: Partial Discharge Imaging for Large Motors and Generators]]></title><link>https://easa.com/resources/resource-library/seeing-the-invisible-partial-discharge-imaging-for-large-motors-and-generators</link><description><![CDATA[ Chase Fell  
Technical Education Committee Chair 
Jay Industrial Repair 

 For service professionals working with large electric motors and generators, machines with voltage ratings 5 kV and ...]]></description><pubDate>Tue, 01 Jul 2025 05:05:00 GMT</pubDate><guid>https://easa.com/resources/resource-library/seeing-the-invisible-partial-discharge-imaging-for-large-motors-and-generators</guid><dc:identifier><![CDATA[254e0687-d427-4b59-9b7b-a507e4dcb9f6-3791]]></dc:identifier></item><item><dc:creator><![CDATA[William]]></dc:creator><title><![CDATA[Viendo lo Invisible: Imágenes de Descargas Parciales en Motores y Generadores Grandes]]></title><link>https://easa.com/resources/resource-library/viendo-lo-invisible-im225genes-de-descargas-parciales-en-motores-y-generadores-grandes</link><description><![CDATA[ Chase Fell 
Presidente del Comité de Enseñanza Técnica 
Jay Industrial Repair 

 Para los profesionales que trabajan con grandes motores y generadores eléctricos, las máquinas con tensiones ...]]></description><pubDate>Tue, 01 Jul 2025 05:00:00 GMT</pubDate><guid>https://easa.com/resources/resource-library/viendo-lo-invisible-im225genes-de-descargas-parciales-en-motores-y-generadores-grandes</guid><dc:identifier><![CDATA[254e0687-d427-4b59-9b7b-a507e4dcb9f6-3796]]></dc:identifier></item><item><dc:creator><![CDATA[William]]></dc:creator><title><![CDATA[Performing a Single-Phase Rotor Test on an Assembled Three-Phase Induction Motor]]></title><link>https://easa.com/resources/resource-library/performing-a-single-phase-rotor-test-on-an-assembled-three-phase-induction-motor</link><description><![CDATA[ This video provides a comprehensive guide on performing a single-phase rotor test on a three-phase squirrel cage motor to check for open rotor bars. It begins with an introduction to the test's ...]]></description><pubDate>Mon, 12 May 2025 17:13:00 GMT</pubDate><guid>https://easa.com/resources/resource-library/performing-a-single-phase-rotor-test-on-an-assembled-three-phase-induction-motor</guid><dc:identifier><![CDATA[254e0687-d427-4b59-9b7b-a507e4dcb9f6-3761]]></dc:identifier></item></channel></rss>