﻿<?xml version="1.0" encoding="utf-8"?><!--RSS Genrated: Sat, 14 Mar 2026 12:53:39 GMT--><rss version="2.0" xmlns:atom="http://www.w3.org/2005/Atom" xmlns:dc="http://purl.org/dc/elements/1.1/" xmlns:content="http://purl.org/rss/1.0/modules/content/" xmlns:ev="http://purl.org/rss/1.0/modules/event/"><channel><title>EASA | The Electro•Mechanical Authority - Transformers</title><link>https://easa.com:443/resources/resource-library/rss/category/2680/transformers</link><atom:link href="https://easa.com:443/resources/resource-library/rss/category/2680/transformers" rel="self" type="application/rss+xml" /><description>RSS document</description><item><dc:creator><![CDATA[Super]]></dc:creator><title><![CDATA[EASA Technical Manual]]></title><link>https://easa.com/resources/resource-library/easa-technical-manual-1</link><description><![CDATA[   

   REVISED September 2022!   

 The EASA Technical Manual, containing more than 900 pages of information specific to electric motor service centers, is available FREE to EASA members as ...]]></description><pubDate>Tue, 20 Sep 2022 14:00:00 GMT</pubDate><guid>https://easa.com/resources/resource-library/easa-technical-manual-1</guid><dc:identifier><![CDATA[254e0687-d427-4b59-9b7b-a507e4dcb9f6-1816]]></dc:identifier></item><item><dc:creator><![CDATA[William]]></dc:creator><title><![CDATA[EASA AR200-2021: Guide For The Repair Of Dry-Type Transformers]]></title><link>https://easa.com/resources/resource-library/easa-ar200</link><description><![CDATA[ EASA announces the publication of an update to  AR200 , now titled the  Guide For The Repair Of Dry-Type Transformers . This guide outlines best practices for the repair of dry-type transformers. ...]]></description><pubDate>Sun, 01 Aug 2021 14:10:00 GMT</pubDate><guid>https://easa.com/resources/resource-library/easa-ar200</guid><dc:identifier><![CDATA[254e0687-d427-4b59-9b7b-a507e4dcb9f6-3001]]></dc:identifier></item><item><dc:creator><![CDATA[Super]]></dc:creator><title><![CDATA[Transformer basics: How they operate, their many features]]></title><link>https://easa.com/resources/resource-library/transformer-basics-how-they-operate-their-many-features-1</link><description><![CDATA[ Richard Huber, P.E. 
Richard Huber Engineering, Ltd. 

 Transformers are fundamental to an industrial or utility distribution or transmission system. This article will present basic transformer ...]]></description><pubDate>Sat, 05 Apr 2014 00:00:00 GMT</pubDate><guid>https://easa.com/resources/resource-library/transformer-basics-how-they-operate-their-many-features-1</guid><dc:identifier><![CDATA[254e0687-d427-4b59-9b7b-a507e4dcb9f6-1955]]></dc:identifier></item><item><dc:creator><![CDATA[Super]]></dc:creator><title><![CDATA[Dissolved gas analysis for oil filled transformers]]></title><link>https://easa.com/resources/resource-library/dissolved-gas-analysis-for-oil-filled-transformers-1</link><description><![CDATA[ Richard Huber, P.E. 
Richard Huber Engineering, Ltd. 

 The intent of this article is to provide an overview of the more common techniques used for dissolved gas analysis (DGA) of mineral oil. ...]]></description><pubDate>Mon, 05 Mar 2012 00:00:00 GMT</pubDate><guid>https://easa.com/resources/resource-library/dissolved-gas-analysis-for-oil-filled-transformers-1</guid><dc:identifier><![CDATA[254e0687-d427-4b59-9b7b-a507e4dcb9f6-2032]]></dc:identifier></item><item><dc:creator><![CDATA[Super]]></dc:creator><title><![CDATA[Aluminum-to-copper magnet wire winding conversions: Considerations for deciding whether wire area should be reduced]]></title><link>https://easa.com/resources/resource-library/aluminum-to-copper-magnet-wire-winding-conversions-considerations-for-deciding-whether-wire-area-should-be-reduced-1</link><description><![CDATA[ Tom Bishop, P.E. 
EASA Senior Technical Support Specialist 

 Although aluminum magnet wire theoretically can be converted to copper magnet wire of about 5/8 of the original wire area, in some ...]]></description><pubDate>Mon, 05 Dec 2011 00:00:00 GMT</pubDate><guid>https://easa.com/resources/resource-library/aluminum-to-copper-magnet-wire-winding-conversions-considerations-for-deciding-whether-wire-area-should-be-reduced-1</guid><dc:identifier><![CDATA[254e0687-d427-4b59-9b7b-a507e4dcb9f6-2041]]></dc:identifier></item><item><dc:creator><![CDATA[Keerthana]]></dc:creator><title><![CDATA[Replacing aluminum conductors with copper conductors in power and distribution transformers up to 10 MVA]]></title><link>https://easa.com/resources/resource-library/replacing-aluminum-conductors-with-copper-conductors-in-power-and-distribution-transformers-up-to-10-mva-1</link><description><![CDATA[ Richard Huber, P. Eng. 
Richard Huber Engineering, Ltd. 
North Vancouver, British Columbia 
Canada 
Technical Services Committee Member 

   Introduction   
There are many transformers in use ...]]></description><pubDate>Thu, 05 Aug 2010 00:00:00 GMT</pubDate><guid>https://easa.com/resources/resource-library/replacing-aluminum-conductors-with-copper-conductors-in-power-and-distribution-transformers-up-to-10-mva-1</guid><dc:identifier><![CDATA[254e0687-d427-4b59-9b7b-a507e4dcb9f6-2088]]></dc:identifier></item></channel></rss>