Electrical Tests: The Good, the Bad and the Ugly

  • July 2013
  • Number of views: 4775
  • Article rating: No rating

Chuck Yung
EASA Senior Technical Support Specialist

Although the rotating equipment repair industry has been around for over a century, technology continues to introduce new test instruments and procedures. Some of these are good: surge test, growler, core loss test; some are bad: core testing a rotor at 60 times its operating frequency, or performing a Hipot at several times the prescribed value; and some are just plain ugly.

This paper will help you to sort out which are which, and help educate your customers as to the reasons why. Standards organizations (IEEE, ANSI, IEC) have developed specific tests, with much scientific thought as to how stringent a test should be. ANSI/EASA AR100: Recommended Practice for the Repair of Rotating Electrical Apparatus consistently references the relevant standard(s) for each test.

This paper, presented at the 2013 EASA Convention, summarizes the accepted and other electrical tests required by motor and generator end users. It covers:

  • Various standards (IEEE, IEC, NEMA, ANSI and API) that describe and legitimize most of the tests used by our industry
  • Other tests, not supported by any recognized standards, that end users request repairers to perform
  • An outline of these tests, with supporting standards, which should be useful when discussing testing requirements with end users

LOGIN TO DOWNLOAD THE PAPER



Rate this article:
No rating
Print


PREVIOUS ITEM
Comments are only visible to subscribers.

Getting The Most From Your Electric Motors

Getting The Most From Your Electric Motors - coverThis 40-page booklet provides great advice for obtaining the longest, most efficient and cost-effective operation from general and definite purpose electric motors.

This booklet covers topics such as:

  • Installation, startup and baseline information
  • Operational monitoring and maintenance
  • Motor and baseline installation data
  • How to read a motor nameplate
  • Motor storage recommendations

LEARN MORE AND DOWNLOAD MÁS INFORMACIÓN Y DESCARGAR BUY PRINTED COPIES

READ MORE ABOUT THE FEATURES AND BENEFITS

EASA/AEMT Rewind Study

EASA Rewind Study cover

The Effect of Repair/Rewinding on Premium Efficiency/IE3 Motors
Tests prove Premium Efficiency/IE3 Motors can be rewound without degrading efficiency.

DOWNLOAD THE FULL RESULTS

ANSI/EASA AR100-2020

ANSI/EASA AR100-2015 cover

Recommended Practice for the Repair of Rotating Electrical Apparatus
This is a must-have guide to the repair of rotating electrical machines. Its purpose is to establish recommended practices in each step of the rotating electrical apparatus rewinding and rebuilding processes.

DOWNLOAD - ENGLISH

DESCARGAR - ESPAÑOL

EASA Technical Manual

EASA Technical Manual cover

Revised May 2024
The EASA Technical Manual is the association's definitive and most complete publication. It's available FREE to members in an online format. Members can also download PDFs of the entire manual or individual sections.

VIEW & DOWNLOAD