Performing a Single-Phase Rotor Test on an Assembled Three-Phase Induction Motor - ANSI Accredited Standards Developer Information - EASA | The Electro•Mechanical Authority
Facebook Twitter LinkedIn YouTube Menu Search Arrow Right Arrow Left Arrow Down Arrow Up Home Arrow Next Arrow Previous RSS Icon Calendar Icon Warning Icon

ANSI/EASA AR100-2020 cover

ANSI/EASA Standard AR100-2020
ANSI/EASA AR100-2020: Recommended Practice for the Repair of Rotating Electrical Apparatus is a must-have guide to the repair of rotating electrical machines. It establishes recommended practices in each step of the rotating electrical apparatus rewinding and rebuilding processes.

LEARN MORE & DOWNLOAD

Questions?

For information about ANSI/EASA AR100 or questions about the work on this standard, contact:

Mike Howell, PE
EASA Technical Support Specialist
+1 314 993 2220
mhowell@easa.com

ANSI Accredited Standards Developer Information

Performing a Single-Phase Rotor Test on an Assembled Three-Phase Induction Motor

  • May 2025
  • Number of views: 884
  • Article rating: No rating
Recording duration: 8:28

This video provides a comprehensive guide on performing a single-phase rotor test on a three-phase squirrel cage motor to check for open rotor bars. It begins with an introduction to the test's purpose and the importance of ensuring the stator winding is free from grounds, shorts, or opens by conducting preliminary tests such as insulation resistance, surge, and lead-to-lead resistance tests. The video then details the identification and setup of the necessary test instruments, including a single-phase power supply, digital voltmeter, and clamp-on amp meter.

The procedure involves correctly connecting the stator for the test, applying single-phase voltage, and measuring the maximum and minimum amperage during the test. By rotating the motor shaft manually and monitoring the current with a clamp-on amp meter, viewers can note the highest and lowest current values. The video explains how to calculate the test current variation and interpret the results to determine if the rotor has open bars. If the current deviation exceeds 3%, it indicates a probable open rotor bar.

Safety is emphasized throughout the video, with instructions on wearing proper protective equipment and ensuring all electrical connections are secure and isolated. The video also covers the safe disconnection of stator leads after the test and the importance of following company safety practices. The single-phase rotor test is highlighted as a simple yet effective method for assessing the condition of a rotor in a service center environment, where various voltage supplies are available. The video concludes by encouraging viewers to apply these techniques in their motor repair practices.



Print


Comments are only visible to subscribers.

EASA Rewind Study cover

The Effect of Repair/Rewinding on Premium Efficiency/IE3 Motors
Tests prove Premium Efficiency/IE3 Motors can be rewound without degrading efficiency.

DOWNLOAD THE FULL RESULTS

BUY PRINTED COPIES

EASA Good Practice Guide

Good Practice Guide to Maintain Motor Efficiency
Based on the 2019 and 2003 Rewind Studies of premium efficiency, energy efficient, IE2 (formerly EF1) and IE3 motors