Facebook Twitter LinkedIn YouTube Menu Search Arrow Right Arrow Left Arrow Down Arrow Up Home Arrow Next Arrow Previous RSS Icon Calendar Icon Warning Icon

ANSI/EASA AR100-2020 cover

ANSI/EASA Standard AR100-2020
ANSI/EASA AR100-2020: Recommended Practice for the Repair of Rotating Electrical Apparatus is a must-have guide to the repair of rotating electrical machines. It establishes recommended practices in each step of the rotating electrical apparatus rewinding and rebuilding processes.

LEARN MORE & DOWNLOAD

Questions?

For information about ANSI/EASA AR100 or questions about the work on this standard, contact:

Mike Howell, PE
EASA Technical Support Specialist
+1 314 993 2220
mhowell@easa.com

ANSI Accredited Standards Developer Information

Principles of Medium & Large AC Motors, 1st Edition - IEC

  • February 2020
  • Number of views: 55837
  • Article rating: 4.3

This manual covers horizontal and vertical squirrel-cage induction motors in the 300 to 5,000 horsepower range, low- and medium-voltage. Most of the principles covered apply to other sizes as well. This manual focuses primarily on IEC motors and standards.

Consideraciones para los Amperios Inrush vs Rotor Bloqueado

  • June 2021
  • Number of views: 28976
  • Article rating: 3.6

Cuando se energiza inicialmente un motor de CA a su voltaje nominal (y frecuencia), el motor toma varias veces la corriente nominal hasta que alcanza toda la velocidad de operación. Las consecuencias de la corriente de arranque incluyen: Breve sobrecalentamiento de los bobinados del estator y del rotor, disparos no deseados de los dispositivos de protección y caídas de voltaje en el suministro eléctrico.

Rotor/Armature Core Test Form

  • September 2019
  • Number of views: 22405
  • Article rating: 3.0

EASA’s Rotor/Armature Core Test Form provides a step-by-step procedure for calculating the number of turns and cable size required for a loop test.

Considerations for Inrush vs. Locked Rotor Amps

  • June 2021
  • Number of views: 14587
  • Article rating: 1.0

When an AC motor is initially energized at rated voltage (and frequency), the current drawn is many times rated current until the motor attains full operating speed. Consequences of starting current include short time overheating of stator windings and rotors, undesirable operation of overload protective devices and a sag in the supply voltage.

Advanced rotor bar testing with surface magnetic field measurements

  • April 2018
  • Number of views: 9693
  • Article rating: No rating

Traditional rotor bar defect detection systems are often insufficient in sensitivity, record-ability and numerical analysis of test results. Many means of rotor defect detection require the motor to be fully assembled with a functional stator. These limitations have laid the groundwork for the development of a new rotor defect detection technique.

Prueba avanzada de un rotor de barras con mediciones de campo magnético de superficie

  • April 2018
  • Number of views: 8531
  • Article rating: No rating

Los sistemas tradicionales para la detección de defectos en las barras de un rotor a menudo son insuficientes en sensibilidad, capacidad de registro y análisis numérico de los resultados de la prueba. Muchos medios para la detección de los defectos de un rotor requieren que el motor esté completamente ensamblado con un estator funcional. Estas limitaciones han establecido las bases para desarrollar una nueva técnica de detección de defectos en el rotor.

EASA Rewind Study cover

The Effect of Repair/Rewinding on Premium Efficiency/IE3 Motors
Tests prove Premium Efficiency/IE3 Motors can be rewound without degrading efficiency.

DOWNLOAD THE FULL RESULTS

BUY PRINTED COPIES

EASA Good Practice Guide

Good Practice Guide to Maintain Motor Efficiency
Based on the 2019 and 2003 Rewind Studies of premium efficiency, energy efficient, IE2 (formerly EF1) and IE3 motors

LEARN MORE & DOWNLOAD