Solve vertical pump motor vibration

Knowledge of common vibratory forces helps diagnose and correct problems

  • February 2017
  • Number of views: 15837
  • Article rating: No rating

By Gene Vogel
EASA Pump & Vibration Specialist

High vibration is a common problem for motors that are installed on top of vertical pumps. Its source can be a mechanical issue with the pump, motor or coupling or even hydraulic forces from the pump. Structural issues involving “reed frequency” resonance often amplify the problem, but effective diagnosis must begin with an understanding of the underlying vibratory forces. Although the general vertical pump category includes submersibles, this article focuses solely on the ones that most commonly exhibit high-vibration conditions: surface-mounted pumps with the motor bolted to a pedestal on top.

Topics covered in this article include:

  • Mass unbalance
  • Coupling type and alignment
  • Mechanical action of pump shaft & impeller
  • Hydraulic action of fluid
  • Resonant frequencies
  • Basic frequency analysis
  • Trim balancing
  • Other possibilities
  • Vertical pump troubleshooting checklist

READ THE ARTICLE



Print


Comments are only visible to subscribers.

EASA Rewind Study cover

The Effect of Repair/Rewinding on Premium Efficiency/IE3 Motors
Tests prove Premium Efficiency/IE3 Motors can be rewound without degrading efficiency.

DOWNLOAD THE FULL RESULTS

BUY PRINTED COPIES

EASA Good Practice Guide

Good Practice Guide to Maintain Motor Efficiency
Based on the 2019 and 2003 Rewind Studies of premium efficiency, energy efficient, IE2 (formerly EF1) and IE3 motors

LEARN MORE & DOWNLOAD