Facebook Twitter LinkedIn YouTube Menu Search Arrow Right Arrow Left Arrow Down Arrow Up Home Arrow Next Arrow Previous RSS Icon Calendar Icon Warning Icon

ANSI/EASA AR100-2020 cover

ANSI/EASA Standard AR100-2020
ANSI/EASA AR100-2020: Recommended Practice for the Repair of Rotating Electrical Apparatus is a must-have guide to the repair of rotating electrical machines. It establishes recommended practices in each step of the rotating electrical apparatus rewinding and rebuilding processes.

LEARN MORE & DOWNLOAD

Questions?

For information about ANSI/EASA AR100 or questions about the work on this standard, contact:

Mike Howell, PE
EASA Technical Support Specialist
+1 314 993 2220
mhowell@easa.com

ANSI Accredited Standards Developer Information

Principles of Medium & Large AC Motors, 1st Edition - IEC

  • February 2020
  • Number of views: 57100
  • Article rating: 3.9

This manual covers horizontal and vertical squirrel-cage induction motors in the 300 to 5,000 horsepower range, low- and medium-voltage. Most of the principles covered apply to other sizes as well. This manual focuses primarily on IEC motors and standards.

Electrical Engineering Pocket Handbook

  • August 2018
  • Number of views: 23681
  • Article rating: 5.0

Filled with practical information, this 118-page handbook (3.5" x 6", 9cm x 15cm) makes a great “give-away” item for your customers and potential customers! Buy this great resource as is OR imprint your company logo and information on the cover to turn it into a great marketing piece for your salespeople!

Working with moisture sensors in submersible pumps

  • June 2019
  • Number of views: 16610
  • Article rating: 4.2

Submersible pumps may have any of several types of internal sensors or protective devices. These may include temperature sensors, vibration transducers or moisture sensors. The type of temperature and vibration devices are identical to those used in non-submersible style motors, so only the moisture sensors are of special interest regarding submersible pumps. It is important for technicians involved in the repair of submersible pumps to be aware of their presence in any specific pump they may encounter, and understand the manner in which they function to ensure they work properly after repairs are completed.

Uso de sensores de humedad en bombas sumergibles

  • June 2019
  • Number of views: 14369
  • Article rating: 4.5

Las bombas sumergibles pueden tener diferentes tipos de sensores o dispositivos de protección internos, los cuales pueden ser sensores de temperatura, transductores de vibración o sensores de humedad. Los sensores de temperatura y de vibración son idénticos a los utilizados en los motores no sumergibles, por lo que solo los sensores de humedad guardan especial relación con las bombas sumergibles. Es importante que los técnicos involucrados en la reparación de las bombas sumergibles sean conscientes de su presencia en cualquier bomba en los que se puedan encontrar y que comprendan como trabajan para asegurarse que funcionan correctamente después de terminar los trabajos de reparación.

Increasing Motor Reliability

Regularly Checking the Operating Temperature of Critical Motors Will Help Extend Their Life and Prevent Costly, Unexpected Shutdowns

  • February 2020
  • Number of views: 13457
  • Article rating: 3.3

Regardless of the method used to detect winding temperature, the total, or hot spot, temperature is the real limit; and the lower it is, the better. Don’t let excessive heat kill your motors before their time.

Practical advice for motor protection

New IEEE standard provides guidance for motor protection for industrial and commercial applications

  • March 2018
  • Number of views: 10061
  • Article rating: No rating

The Institute of Electrical and Electronics Engineers (IEEE) has published a new standard: IEEE Std. 3004.8-2016, “Recommended Practice for Motor Protection in Industrial and Commercial Power Systems.” If you’re an electrical professional who deals with a broad spectrum of motor protection schemes, including low- and medium-voltage AC and DC motors, then you need to become familiar with this standard.

Motor protection and control tips, procedures

  • May 2005
  • Number of views: 9812
  • Article rating: No rating

This series of four articles covers many schemes of motor protection and control.

A closer look: Winding protection device can prevent permanent damage to motor

  • March 2002
  • Number of views: 9445
  • Article rating: 4.5

There are a number of different types of winding protection devices used with motors. However, they all basically do the same thing; they sense a change from the normal operating temperature and either sound an alarm or take the motor off line when the specified temperature limit has been met or exceeded. Temperature protection is not limited to just large motors. A smaller motor that is critical to operation would be a good candidate for winding temperature protection if a failure would cause significant costs due to downtime.

Help With Installing Winding Resistance Temperature Detectors (RTDs)

  • May 2019
  • Number of views: 8786
  • Article rating: 4.7

Getting the Most from Winding RTDs

  • April 2021
  • Number of views: 7251
  • Article rating: No rating

Winding RTDs are resistance-based temperature monitoring devices. Aside from just reporting winding temperature, here are some tips for maximizing the benefit of RTDs.

EASA Rewind Study cover

The Effect of Repair/Rewinding on Premium Efficiency/IE3 Motors
Tests prove Premium Efficiency/IE3 Motors can be rewound without degrading efficiency.

DOWNLOAD THE FULL RESULTS

BUY PRINTED COPIES

EASA Good Practice Guide

Good Practice Guide to Maintain Motor Efficiency
Based on the 2019 and 2003 Rewind Studies of premium efficiency, energy efficient, IE2 (formerly EF1) and IE3 motors