A case of uneven brush wear

  • October 1998
  • Number of views: 11225
  • Article rating: 4.0

Chuck Yung
EASA Senior Technical Support Specialist

The brushes on a 4-pole, 700 hp DC motor were not wearing at the same rate. In this case, rapid brush wear occurred on two adjacent brush rows - one positive and one negative polarity. The other brushes had minimal wear. Electrical tests found no winding faults, and the air supply was clean. Most of us suspect low current-density when rapid brush wear occurs. A lightly loaded DC motor can "dust" a set of brushes in short order. Changing the brush grade (or removing some of the brushes) will usually solve the problem.

LOGIN TO DOWNLOAD THE ARTICLE



0Upvote 0Downvote
Rate this article:
4.0
Print


Comments are only visible to subscribers.

EASA Rewind Study cover

The Effect of Repair/Rewinding on Premium Efficiency/IE3 Motors
Tests prove Premium Efficiency/IE3 Motors can be rewound without degrading efficiency.

DOWNLOAD THE FULL RESULTS

BUY PRINTED COPIES

EASA Good Practice Guide

Good Practice Guide to Maintain Motor Efficiency
Based on the 2019 and 2003 Rewind Studies of premium efficiency, energy efficient, IE2 (formerly EF1) and IE3 motors

LEARN MORE & DOWNLOAD