Understand O-Rings in Submersible Pump Maintenance & Repair Process - Webinar Recordings - EASA | The Electro•Mechanical Authority
Facebook Twitter LinkedIn YouTube Menu Search Arrow Right Arrow Left Arrow Down Arrow Up Home Arrow Next Arrow Previous RSS Icon Calendar Icon Warning Icon

Filter the results

  • Enter one or more words to find resources containing any of the words entered
  • Enter words or phrases between " " to find exact match

Webinar Recordings

Trade press article — Pumps & Systems

Understand O-Rings in Submersible Pump Maintenance & Repair Process

Inspect compression surfaces thoroughly to help ensure leak-free repairs

  • June 2014
  • Number of views: 12094
  • Article rating:

A leak rate of one drip per minute equals about a liter (quart) of water in three days. For an O-ring on a submersible pump, that is a major problem. O-rings are often used for static seals on submersible pumps. Understanding what makes a good static seal and what causes one to leak is important for pump maintenance and repair technicians.

The effectiveness of an O-ring static seal depends on the dimensions of the mating parts, the surface finish of the mating parts and the characteristics of the elastomeric O-ring. The focus of this article is the dimensions and condition of the mating parts.

Topics covered in the article include:

  • Dimensions
  • Identification of critical surfaces
  • A case study

READ THE FULL ARTICLE