A leak rate of one drip per minute equals about a liter (quart) of water in three days. For an O-ring on a submersible pump, that is a major problem. O-rings are often used for static seals on submersible pumps. Understanding what makes a good static seal and what causes one to leak is important for pump maintenance and repair technicians.
The effectiveness of an O-ring static seal depends on the dimensions of the mating parts, the surface finish of the mating parts and the characteristics of the elastomeric O-ring. The focus of this article is the dimensions and condition of the mating parts.
Topics covered in the article include:
- Dimensions
- Identification of critical surfaces
- A case study
READ THE FULL ARTICLE
ANSI/EASA AR100
More information on this topic can be found in ANSI/EASA AR100- Section 2: Mechanical repair