Repair/Replace: What to Do When the Decision Is to Replace - ANSI Accredited Standards Developer Information - EASA | The Electro•Mechanical Authority
Facebook Twitter LinkedIn YouTube Menu Search Arrow Right Arrow Left Arrow Down Arrow Up Home Arrow Next Arrow Previous RSS Icon Calendar Icon Warning Icon

ANSI/EASA AR100-2020 cover

ANSI/EASA Standard AR100-2020
ANSI/EASA AR100-2020: Recommended Practice for the Repair of Rotating Electrical Apparatus is a must-have guide to the repair of rotating electrical machines. It establishes recommended practices in each step of the rotating electrical apparatus rewinding and rebuilding processes.

LEARN MORE & DOWNLOAD

Questions?

For information about ANSI/EASA AR100 or questions about the work on this standard, contact:

Mike Howell, PE
EASA Technical Support Specialist
+1 314 993 2220
mhowell@easa.com

ANSI Accredited Standards Developer Information

Repair/Replace: What to Do When the Decision Is to Replace

  • June 2007
  • Number of views: 49
  • Article rating: No rating

Tom Bishop
Technical Support Specialist
Electrical Apparatus Service Association
St. Louis, MO

The paper "Repair/Replace: What to Do When the Decision Is to Replace" by Tom Bishop, presented at the EASA Convention 2007, addresses the considerations and steps involved when the decision is made to replace an electric motor rather than repair it. This comprehensive guide covers selecting the right motor for the application, dealing with usual and unusual electrical and mechanical conditions, preventing problems by recognizing the causes of the original motor failure, and adding value by providing additional features and services to increase the reliability of the replacement motor.

The paper begins by emphasizing the importance of evaluating both the application and motor characteristics to ensure the replacement motor is suitably matched to the application. Key factors include environmental conditions, load inertia, speed versus torque, starting methods, and mechanical coupling and mounting. The author provides a detailed list of questions to ask to better assure proper motor selection, such as obtaining complete nameplate information, understanding the driven equipment, and knowing the motor's past history and operating environment.

Next, the paper discusses dealing with usual and unusual service conditions as defined by NEMA MG1 standards. Usual conditions include ambient temperature ranges, altitude, rigid mounting surfaces, and operation within specified voltage and frequency tolerances. Unusual conditions encompass exposure to hazardous materials, abnormal mechanical loads, and operation in extreme environments. Recognizing these conditions helps in selecting or modifying the replacement motor to fit the specific application needs.

Preventing problems by recognizing the causes of the original motor failure is another critical aspect covered in the paper. The author highlights the importance of root cause failure analysis, which involves inspecting and evaluating all motor components to determine the primary cause of failure. Common failure modes for stator windings, rotors, bearings, shafts, and cooling systems are discussed, along with diagnostic methods to identify and address these issues.

Finally, the paper explores adding value by providing additional features and services to enhance the reliability of the replacement motor. These include equipping motors with bearing and winding temperature sensing, surge protection, shaft seals, and insulated bearings. The author also suggests offering value-added services such as predictive maintenance (PdM), preventive maintenance (PM), and motor management to help end users maintain their motor inventory and prevent future failures.

Key Points Covered:

  • Selecting the right motor for the application
  • Dealing with usual and unusual service conditions
  • Preventing problems by recognizing the causes of original motor failure
  • Adding value by providing additional features and services

Key Takeaways:

  • Proper motor selection involves evaluating both application and motor characteristics.
  • Recognizing usual and unusual service conditions helps in selecting or modifying the replacement motor.
  • Root cause failure analysis is essential to prevent premature failure of the replacement motor.
  • Providing additional features and services can significantly enhance the reliability and lifespan of the replacement motor.


0Upvote 0Downvote
Rate this article:
No rating
Print


Comments are only visible to subscribers.

EASA Rewind Study cover

The Effect of Repair/Rewinding on Premium Efficiency/IE3 Motors
Tests prove Premium Efficiency/IE3 Motors can be rewound without degrading efficiency.

DOWNLOAD THE FULL RESULTS

BUY PRINTED COPIES

EASA Good Practice Guide

Good Practice Guide to Maintain Motor Efficiency
Based on the 2019 and 2003 Rewind Studies of premium efficiency, energy efficient, IE2 (formerly EF1) and IE3 motors

LEARN MORE & DOWNLOAD