Why “White Coils” are a “Red Flag”

The importance of preventing the ingress of air during global vacuum pressure impregnation of form-coil windings

  • September 2022
  • Number of views: 6794
  • Article rating: 3.3

David Sattler
L&S Electric

The goal of vacuum pressure impregnation is complete saturation of a winding with insulating resin. As resin penetrates the insulating materials, it causes them to darken. When VPI resin is drained from the winding, all end-turn insulation should be darkened to a uniform shade. Connection insulation should also show uniform darkening. If some insulation is a lighter shade, the coil or jumper is not fully saturated. The winding is not properly protected, and if the problem is not addressed, it is likely to cause premature failure of the unit. This could result in costly warranty work, or at a minimum, will be a failure to provide your customers with the quality they expect and deserve.

LOGIN TO VIEW AND DOWNLOAD THE ARTICLE AVAILABLE IN SPANISH

Print


Comments are only visible to subscribers.

EASA Rewind Study cover

The Effect of Repair/Rewinding on Premium Efficiency/IE3 Motors
Tests prove Premium Efficiency/IE3 Motors can be rewound without degrading efficiency.

DOWNLOAD THE FULL RESULTS

BUY PRINTED COPIES

EASA Good Practice Guide

Good Practice Guide to Maintain Motor Efficiency
Based on the 2019 and 2003 Rewind Studies of premium efficiency, energy efficient, IE2 (formerly EF1) and IE3 motors

LEARN MORE & DOWNLOAD