Service factor: What is it and what does it do?

  • August 2015
  • Number of views: 22841
  • Article rating: 2.0

Jim Bryan
EASA Technical Support Specialist (retired)

There are many misconceptions about Service Factor (SF) in the industry. Some feel it is meant for temporary excursions into overload conditions; others consider it to be an allowance for permanent overload. The truth is that it is neither. As defined in the EASA Technical Manual and NEMA MG1, the definition of service factor is:

"A multiplier which, when applied to rated power, indicates a permissible power loading that may be carried under the conditions specified for the service factor."

The NEMA MG1-2011 theory of SF says that a motor is thermally capable of overload to that point within the insulation class at normal service conditions.

Since any increase in load increases the current, this overload will increase the operating temperature of the motor. For every increase of 10ºC, the motor winding expected life is reduced by one-half. It does not matter what the source of that increase in temperature is; overload, poor ventilation, low voltage or high ambient temperature are just a few.

LOGIN TO DOWNLOAD THE ARTICLE



0Upvote 0Downvote
Rate this article:
2.0
Print


Comments are only visible to subscribers.

EASA Rewind Study cover

The Effect of Repair/Rewinding on Premium Efficiency/IE3 Motors
Tests prove Premium Efficiency/IE3 Motors can be rewound without degrading efficiency.

DOWNLOAD THE FULL RESULTS

BUY PRINTED COPIES

EASA Good Practice Guide

Good Practice Guide to Maintain Motor Efficiency
Based on the 2019 and 2003 Rewind Studies of premium efficiency, energy efficient, IE2 (formerly EF1) and IE3 motors

LEARN MORE & DOWNLOAD