Facebook Twitter LinkedIn YouTube Menu Search Arrow Right Arrow Left Arrow Down Arrow Up Home Arrow Next Arrow Previous RSS Icon Calendar Icon Warning Icon

Articles in Industry Publications

Understand O-Rings in Submersible Pump Maintenance & Repair Process

Inspect compression surfaces thoroughly to help ensure leak-free repairs

  • June 2014
  • Number of views: 9130
Trade press article — Pumps & Systems

A leak rate of one drip per minute equals about a liter (quart) of water in three days. For an O-ring on a submersible pump, that is a major problem. O-rings are often used for static seals on submersible pumps. Understanding what makes a good static seal and what causes one to leak is important for pump maintenance and repair technicians.