When a core loss test reveals localized hot spots, or visual inspection identifies physical damage, the ability to repair the damage in a cost-effective manner means the difference between repair or replacement.
Convention presentation
Revisit EASA's 2024 Convention & Solutions Expo by buying access to recordings of the general sessions and education events streamed from EASA's website! These recordings provide just over 32 hours of training. Downloadable PDFs of slides and technical papers are included!
FREE for Members of EASA
Webinar recording
Learn how to effectively use EASA's live, ever-expanding online database of more than 250,000 windings.
Article
With the advent of solid-state electronic variable frequency drives (VFDs) in the late 1980s, it was found that the windings of motors used on VFDs failed more frequently than when powered by a utility (sine wave) supply. By the turn of the century, motor manufacturers had gained a better understanding of how VFDs affected motor windings. This article describes the materials and methods associated with inverter duty windings.
Article
Con la llegada de los variadores de frecuencia electrónicos (VFD) de estado sólido a fines de la década de 1980, se descubrió que los bobinados de los motores que funcionaban con VFDs fallaban con más frecuencia que al estar alimentados con la energía convencional (onda sinusoidal). A principios de siglo, los fabricantes de motores habían comprendido mejor cómo los VFD afectaban los devanados del motor, y al igual que los proveedores de materiales electro, aislantes habían desarrollado materiales y métodos para mejorar la confiabilidad de los devanados de los motores alimentados con VFDs. En este artículo, describiremos los materiales y métodos asociados con los devanados inverter duty.
Article
This article explains in layman’s terms what electromechanical professionals refer to as circulating currents, why they exist in three-phase electric motors and to offer practical solutions.
Article
Este artículo es explicar en términos sencillos a qué se refieren los profesionales de la electromecánica como corrientes circulantes, por qué existen en los motores eléctricos trifásicos y ofrecer soluciones prácticas.
FREE for Members of EASA
Webinar recording
Are you encountering high no-load current or high current with load? This presentation will look into the causes and cures.
Article
The insulation system chosen for any rewind should be suitable for the application, the voltage class, and the winding process capability of the service center. In most cases, adherence to “equal to or better than” selection is a good practice.
Article
El sistema de aislamiento escogido para cualquier rebobinado debe ser el adecuado para la aplicación, el voltaje y la capacidad del proceso de rebobinado del centro de servicio. En la mayoría de los casos, seleccionar una opción "igual o mejor" es una buena práctica.
FREE for Members of EASA
Webinar recording
When preparing to rewind random or form-wound status, sometimes there just doesn’t seem to be enough room in the stator slot for the desired conductor area and insulation quantities. This presentation looks at balancing stator copper losses against insulation reliability.
How Using Clamps When Pulling Magnet Wire Helps Prevent Splayed Teeth
Article
Unless great care is taken, pulling magnet wire from a motor stator often bends or splays the lamination’s end teeth. Bent teeth, or teeth that have been splayed outward at the ends of the core stack, will likely compromise the quality of the repair job. Therefore, we have designed and implemented the use of disc clamps to hold the stator tooth tips in place while pulling magnet wire from the slots. The clamping fixtures described in the photos have helped ensure that we avoid damaging the stator teeth during the stripping process.
Cómo el usar discos de retención al tirar del alambre magneto previene doblar los dientes de las laminaciones
Article
A no ser que se tenga mucho cuidado, tirar del alambre magneto al desmantelar el estator de un motor a menudo deforma o dobla los dientes de las laminaciones. Estos dientes deformados comprometerán la calidad de la reparación y hay estudios que demuestran que este problema puede reducir la eficiencia del motor. Sin embargo, aunque esta reducción puede ser pequeña, genera altos costos y desperdicio de energía.
FREE for Members of EASA
Webinar recording
¿Recibió un motor antiguo bobinado con alambre de aluminio? Este webinario explicará como realizar la conversión adecuada de alambre de aluminio a alambre de cobre en máquinas de CA y CC, incluyendo ejemplos para el rebobinado de estatores y campos shunt.
Article
This article looks at some of the import details for a proper concentric to lap winding conversion. It also shows how using the EASA Technical Manual, EASA's AC Motor Verification & Redesign Software, as well as the EASA AC Redesign manual, can help.
Article
Este artículo analiza algunos de los detalles de importación para una conversión adecuada de devanado concéntrico a devanado por vuelta. También muestra cómo puede ayudar el uso del Manual técnico de EASA, el software de rediseño y verificación de motores de CA de EASA, así como el manual de Rediseño de motores AC de EASA.
Article
EASA recommends using the lead wire specified by the original equipment manufacturer (OEM) whenever possible. If not available, some guidance is provided in section 6 of the EASA Technical Manual and an online calculator is available to determine a minimum recommended size based on temperature rating, expected current, number of leads and type of connection. This article will describe the calculator’s function.
Article
EASA recomienda usar el cable de salida especificado por el fabricante original del equipo. Si no está disponible, la sección 6 del Manual técnico de EASA proporciona orientación al respecto y hay una calculadora en línea disponible en go.easa.com/calculators para determinar el tamaño mínimo recomendado según la clasificación de temperatura, la corriente esperada, la cantidad de cables y el tipo de conexión. Este artículo describirá la función de la calculadora.
Article
Occasions arise where original winding data is not available. It may have been recorded incorrectly or a different service center may have stripped the core but not completed the repair. In those cases, the service center must come up with a new “bare core” winding design. EASA's redesign software has some specific features to address this need.
Article
Surgen ocasiones en las que los datos de bobinado originales no están disponibles. Es posible que se haya registrado incorrectamente o que un centro de servicio diferente haya quitado el núcleo pero no haya completado la reparación. En esos casos, el centro de servicio debe presentar un nuevo diseño de bobinado de "núcleo desnudo". El software de rediseño de EASA tiene algunas características específicas para abordar esta necesidad.
FREE for Members of EASA
Webinar recording
Choosing an appropriate lead wire for a new stator winding is an important task. The manufacturer’s information is not always available, or the number of circuits or external connection may have been changed, requiring a redesign of the lead wire.
Article
There are many factors to consider when re-stacking a stator. Those include the materials, core compression, length of the core, vents, spacers, vent construction and more. This article focuses on taking proper measurements when re-stacking a stator core and how to go about stacking the stator to ensure those dimensions are met.
Article
Hay muchos factores que se deben considerar al re apilar el núcleo del estator. Estos incluyen los materiales, la compresión y largo del núcleo, los orificios de ventilación, los espaciadores, la construcción de los orificios de ventilación y más. Este artículo se centra en tomar las medidas adecuadas para volver a apilar el núcleo de un estator y cómo garantizar que se cumpla con esas dimensiones.
Video
This video shows one step in collecting motor winding data: how to measure magnet wire.
Video
This video explains how to check the ground insulation of an AC motor winding using the insulation resistance (IR) test.
Article
This article uses examples to illustrate some of the pitfalls and subtle aspects regarding windings with unequal coil grouping.
Article
Este artículo usa ejemplos para ilustrar algunas de las trampas y aspectos sutiles con respecto a los devanados con agrupamiento desigual de bobinas.
En Español
FREE for Members of EASA
Webinar recording
Para monitorear la temperatura de los bobinados y en los rodamientos se pueden usar diferentes tipos de dispositivos. La correcta identificación de los mismos es importante para determinar el tipo de sensor en casos en los que el dispositivo es desconocido o para escoger el dispositivo correcto para una determinada aplicación.
Article
La mayoría de los bobinados de los estatores de CA instalados por los centros de servicio de EASA son imbricados de doble capa, trifásicos y están balanceados. Pero ¿qué significa que estén balanceados?
Article
Most AC stator windings installed by EASA service centers are balanced, three-phase, two-layer, lap windings. But, what does it mean for such a winding to be balanced?