Trade Press Articles - EASA | The Electro•Mechanical Authority
Facebook Twitter LinkedIn YouTube Menu Search Arrow Right Arrow Left Arrow Down Arrow Up Home Arrow Next Arrow Previous RSS Icon Calendar Icon Warning Icon

Articles in Industry Publications

Temperature Detecting Accessories

  • March 2026
  • Number of views: 377
FREE for Members of EASA
Webinar recording

When equipment fails and customers wait, knowing exactly how to test each temperature-sensing device becomes critical. Don't let temperature accessories be your diagnostic blind spot.

Revisiting Unequal-Turn Windings

  • March 2026
  • Number of views: 921
Article

The purpose of this article is to provide some tips for working with unequal-turn (odd-turn), two-layer lap windings, with emphasis on how to sequence the coils within the group for optimum slot fill.

Revisando los Bobinados con Vueltas Desiguales

  • March 2026
  • Number of views: 256
Article

El propósito de este artículo es brindar consejos para trabajar con bobinados imbricados de dos capas con vueltas desiguales (impares), con énfasis en cómo secuenciar las bobinas dentro del grupo para obtener un llenado óptimo de las ranuras

ANSI/EASA Standard AR100-2025: Recommended Practice for the Repair of Rotating Electrical Apparatus

  • January 2026
  • Number of views: 5415
Booklet

ANSI/EASA AR100 is a must-have guide to the repair of rotating electrical machines. Its purpose is to establish recommended practices in each step of the rotating electrical apparatus rewinding and rebuilding processes.

Norma EASA AR100-2025: Práctica Recomendada para la Reparación de Máquinas Eléctricas Rotativas

  • January 2026
  • Number of views: 708
Booklet

La norma ANSI/EASA AR100 es una guía indispensable para la reparación de máquinas eléctricas rotativas. Su objetivo es establecer las prácticas recomendadas en cada etapa de los procesos de rebobinado y reconstrucción de aparatos eléctricos rotativos.

Concentric to Lap Conversions

  • December 2025
  • Number of views: 1334
FREE for Members of EASA
Webinar recording

This presentation covers the important details for a properly converting a 3 phase winding from concentric to lap.

Identificando cables no marcados en maquinas de 12 terminales con un solo devanado

  • December 2025
  • Number of views: 858
Article

Identificar los cables sin marcar en los motores trifásicos es una tarea habitual para los técnicos de los centros de servicio. Este artículo presenta un método para asignar números a los cables de una máquina de 12 cables con los terminales sin marcar.

Identifying Unmarked Leads in 12-Lead Machines with One Winding

  • December 2025
  • Number of views: 1609
Article

Identifying unmarked leads in three-phase motors is a common task for service center technicians. This article provides one way to assign lead numbers for a 12-lead machine with unmarked leads.

Rebobinando Motores Trifásicos Inverter Duty

  • October 2025
  • Number of views: 1872
FREE for Members of EASA
Webinar recording

Este webinario cubrirá los fallos asociados con los motores trifásicos accionados con variadores electrónicos de frecuencia (VFDs) y como rebobinarlos, rebajando las posibilidades de fallos futuros.

Induction Motor Rotor Windings: Squirrel-Cage and Wound Rotor Basics for the Technician

  • September 2025
  • Number of views: 3164
FREE for Members of EASA
Webinar recording

This presentation covers induction motor basics for squirrel-cage and wound rotor motors.

Consejos para Rebobinar Motores de Grúas de Dos Velocidades con Dos Devanados

  • August 2025
  • Number of views: 1612
Article

Las conversiones de devanados concéntricos a imbricados son una práctica común en muchos centros de servicio de EASA y en la mayoría de los estatores, este cambio es factible y se puede realizar sin dificultad. Sin embargo, en algunos casos, puede resultar muy complicado y generar resultados no deseados debido a la reducción del cobre o la pared de aislamiento.

Seeing the Invisible: Partial Discharge Imaging for Large Motors and Generators

  • July 2025
  • Number of views: 2585
Article

For service professionals working with large electric motors and generators, machines with voltage ratings 5 kV and higher can be vulnerable to invisible threats of partial discharge (PD). Corona and PD activity have long been a challenge to detect before failure occurs. Traditionally, detecting these issues required indirect methods like radio interference voltage (RIV) testing, ultrasonic detection or offline insulation tests. But recent advances in partial discharge imaging—sometimes called corona cameras—are giving engineers and technicians a powerful new tool: the ability to see electrical discharge activity directly and in real time. 

What’s New in NEMA MG 00001-2024 Besides the Title

  • June 2025
  • Number of views: 6393
Article

The 2024 NEMA MG 00001 standard introduces key updates, including new Design BE and CE motors with defined locked-rotor current limits, Class N insulation for high-temperature use, and revised stall time requirements. It adds Super Premium efficiency levels aligned with IEC IE4, adopts IEC voltage/frequency variation guidelines, and expands duty ratings for variable load/speed motors.

Novedades en la NEMA MG 00001-2024 Además del Título

  • June 2025
  • Number of views: 3381
Article

La norma NEMA MG 00001 2024 introduce actualizaciones clave, incluyendo nuevos motores de Diseño BE y CE con límites de corriente de rotor bloqueado definidos, aislamiento Clase N para uso a alta temperatura y requisitos revisados ​​de tiempo de pérdida. Añade niveles de eficiencia Super Premium alineados con IEC IE4, adopta las directrices IEC sobre variación de voltaje/frecuencia y amplía las capacidades de servicio para motores de carga/velocidad variable.

Rewind Tips For 2300-Volt, Random-Wound Motors

  • May 2025
  • Number of views: 3282
Article

From the manufacturer’s perspective, a random-wound, 2300-volt motor represents a substantial reduction in manufacturing cost. For the service center, the challenge is to successfully rewind them while providing a reliable repair. Here are some techniques which will enhance your success rate.

Consejos para rebobinar motores de alambre redondo de 2300 Voltios

  • May 2025
  • Number of views: 2623
Article

Desde la perspectiva del fabricante, un motor de 2300 voltios con bobinado aleatorio representa una reducción sustancial en el costo de fabricación. Para el centro de servicio, el reto es rebobinarlos con éxito y ofrecer una reparación confiable. Aquí hay algunas técnicas que mejorarán su tasa de éxito.

Taking Three-Phase Winding Data

  • April 2025
  • Number of views: 3499
FREE for Members of EASA
Webinar recording

This presentation stresses the importance of taking accurate winding data and explains and emphasizes the consequences of inaccurate data. One of the main benefits of this presentation is to improve ability to “get it right the first time” to avoid the added cost and time of another rewind to correct errors.

Submersible Pump Stator Oil Guidelines

  • November 2024
  • Number of views: 4805
Article

In addition to seal oil, some submersibles have an oil filled stator cavity. The oil in the stator cavity very efficiently transfers heat from the stator winding and core, and especially from the rotor, to the pump casing where convection carries it to the pumpage in which the pump is submerged. While the specifications for seal oil are fairly flexible, stator cavity oil has more constraints.

Pautas Para el Aceite del Estator de las Bombas Sumergibles

  • November 2024
  • Number of views: 3039
Article

Además del aceite de sellado, algunas bombas sumergibles tienen una cavidad del estator llena de aceite. Este aceite transfiere de manera muy eficiente el calor desde el devanado y el núcleo del estator, y especialmente desde el rotor, hasta la carcasa de la bomba, donde la convección lo lleva al líquido de bombeo en el que está sumergida. Si bien las especificaciones para el aceite de sellado son bastante flexibles, el aceite de la cavidad del estator tiene más restricciones.

Identifying Unmarked Leads of Three-Phase Motors

  • October 2024
  • Number of views: 6088
FREE for Members of EASA
Webinar recording

This presentation reviews procedures that explain how to identify unmarked leads of three-phase motors with one or two windings.

Core Repair Tips To Reduce Core Loss

  • August 2024
  • Number of views: 5681
FREE for Members of EASA
Webinar recording

When a core loss test reveals localized hot spots, or visual inspection identifies physical damage, the ability to repair the damage in a cost-effective manner means the difference between repair or replacement.

La Importancia de la Prueba de Impedancia del Estator

  • July 2024
  • Number of views: 3629
FREE for Members of EASA
Webinar recording

Este webinario incluye procedimientos de prueba, resultados esperados y el uso de cámaras termográficas para determinar posibles problemas en las conexiones o en las soldaduras.

Rewind 2024

  • July 2024
  • Number of views: 6565
Convention presentation

Revisit EASA's 2024 Convention & Solutions Expo by buying access to recordings of the general sessions and education events streamed from EASA's website! These recordings provide just over 32 hours of training. Downloadable PDFs of slides and technical papers are included!

Using EASA’s Motor Rewind Data – Version 4

  • June 2024
  • Number of views: 6421
FREE for Members of EASA
Webinar recording

Learn how to effectively use EASA's live, ever-expanding online database of more than 250,000 windings.

Inverter Duty Three-Phase Motor Windings

  • June 2024
  • Number of views: 6960
Article

With the advent of solid-state electronic variable frequency drives (VFDs) in the late 1980s, it was found that the windings of motors used on VFDs failed more frequently than when powered by a utility (sine wave) supply. By the turn of the century, motor manufacturers had gained a better understanding of how VFDs affected motor windings. This article describes the materials and methods associated with inverter duty windings.

Devanados para motores trifásicos Inverter Duty

  • June 2024
  • Number of views: 9048
Article

Con la llegada de los variadores de frecuencia electrónicos (VFD) de estado sólido a fines de la década de 1980, se descubrió que los bobinados de los motores que funcionaban con VFDs fallaban con más frecuencia que al estar alimentados con la energía convencional (onda sinusoidal). A principios de siglo, los fabricantes de motores habían comprendido mejor cómo los VFD afectaban los devanados del motor, y al igual que los proveedores de materiales electro, aislantes habían desarrollado materiales y métodos para mejorar la confiabilidad de los devanados de los motores alimentados con VFDs. En este artículo, describiremos los materiales y métodos asociados con los devanados inverter duty.

Circulating Currents: Causes and Solutions

  • May 2024
  • Number of views: 6140
Article

This article explains in layman’s terms what electromechanical professionals refer to as circulating currents, why they exist in three-phase electric motors and to offer practical solutions. 

Corrientes Circulantes: Causas y Soluciones

  • May 2024
  • Number of views: 4254
Article

Este artículo es explicar en términos sencillos a qué se refieren los profesionales de la electromecánica como corrientes circulantes, por qué existen en los motores eléctricos trifásicos y ofrecer soluciones prácticas.

Examining the Causes of High Motor Current

  • April 2024
  • Number of views: 5612
FREE for Members of EASA
Webinar recording

Are you encountering high no-load current or high current with load? This presentation will look into the causes and cures.

Choosing the Right Insulation System for Medium Voltage Rewinds

  • April 2024
  • Number of views: 6376
Article

The insulation system chosen for any rewind should be suitable for the application, the voltage class, and the winding process capability of the service center. In most cases, adherence to “equal to or better than” selection is a good practice.