Facebook Twitter LinkedIn YouTube Menu Search Arrow Right Arrow Left Arrow Down Arrow Up Home Arrow Next Arrow Previous RSS Icon Calendar Icon Warning Icon

Articles in Industry Publications

Wear ring clearance for centrifugal pumps

Understand the pump specific speed to help establish proper tolerance

  • June 2019
  • Number of views: 20021
Trade press article — Pumps & Systems

One of the most common repairs on centrifugal pumps is replacing worn or damaged wear rings. To restore efficient, reliable operation and prevent catastrophic pump failure, it is critical to restore proper clearances between the stationary casing wear ring and the rotating impeller wear ring. Although many pump manufacturers provide clearances and dimensions, some do not. There are plenty of aging pumps around from now-defunct manufacturers for which dimension data is simply not available.

In such cases, the rule of thumb that follows provides some guidance for acceptable running clearances, or the minimum running clearance chart in American Petroleum Institute (API) Standard 610 can be used as a guide.

Understand O-Rings in Submersible Pump Maintenance & Repair Process

Inspect compression surfaces thoroughly to help ensure leak-free repairs

  • June 2014
  • Number of views: 10617
Trade press article — Pumps & Systems

A leak rate of one drip per minute equals about a liter (quart) of water in three days. For an O-ring on a submersible pump, that is a major problem. O-rings are often used for static seals on submersible pumps. Understanding what makes a good static seal and what causes one to leak is important for pump maintenance and repair technicians.