Facebook Twitter LinkedIn YouTube Menu Search Arrow Right Arrow Left Arrow Down Arrow Up Home Arrow Next Arrow Previous RSS Icon Calendar Icon Warning Icon
NOTICE: The EASA office will be closed Dec. 24, 2024 - January 1, 2025. Technical support will still be available. For quickest response, please use the online support forms or send your inquiry to technicalsupport@easa.com.
EMAIL GENERAL INQUIRY REDESIGN REQUEST

Filter the results

  • Enter one or more words to find resources containing any of the words entered
  • Enter words or phrases between " " to find exact match

Webinar Recordings

Article

Interpoles and Compensating Windings in DC Machines – What Do They Do?

  • December 2023
  • Number of views: 3609
  • Article rating:

Mike Howell, PE
EASA Technical Support Specialist

Unlike their AC counterparts, DC machines do not have rotating magnetic fields. Rather, there are fixed magnetic field axes for the field (direct axis) and armature (quadrature axis). Even though the armature is rotating, the magnetic field axis in the armature is fixed thanks to commutation, which allows the direction of current in an armature conductor to change as it passes from the region under one main field pole to the next. <br><br>LOGIN TO VIEW AND DOWNLOAD THE ARTICLE

AVAILABLE IN SPANISH

Print


Comments are only visible to subscribers.