Facebook Twitter LinkedIn YouTube Menu Search Arrow Right Arrow Left Arrow Down Arrow Up Home Arrow Next Arrow Previous RSS Icon Calendar Icon Warning Icon

How to schedule

To schedule private education for your group, contact:

Dale Shuter, CMP
Meetings & Expositions Manager

+1 314 993 2220, ext. 3335
dshuter@easa.com

1 hour of training

$300 for EASA Chapters/Regions
$400 for member companies
$800 for non-members

How a webinar works

All EASA private webinars are live events in which the audio and video are streamed to your computer over the Internet. Prior to the program, you will receive a web link to join the meeting. 

The presentation portion of the webinar will last about 45 minutes, followed by about 15 minutes of questions and answers.

Requirements

  • Internet connection
  • Computer with audio input (microphone) and audio output (speakers) appropriate for your size group
  • TV or projector/screen

Zoom logo

The Zoom webinar service EASA uses will ask to install a small plugin. Your computer must be configured to allow this in order to have full functionality. Please check with your IT department or company's security policy prior to scheduling a private webinar.

Private Webinars

EASA's private webinars are an inexpensive way to bring an EASA engineer into your service center, place of business or group meeting without incurring travel expenses or lost production time.

Electrical Engineering Pocket Handbook

Electrical Engineering Pocket Handbook

Electrical Engineering Pocket HandbookDESCRIPTION
Filled with practical information, this 118-page handbook (3.5" x 6", 9cm x 15cm) makes a great “give-away” item for your customers and potential customers! Buy this great resource as is OR custom brand your company logo and information on the cover to turn it into a great marketing piece for your salespeople!

BUY COPIES OF THIS HANDBOOK

TABLE OF CONTENTS

MOTOR DATA–ELECTRICAL
Standard Terminal Markings and Connections
DC Motors and Generators (NEMA & IEC Nomenclature)
Field Polarities of DC Machines
General Speed-Torque Characteristics
Full-Load Efficiencies of Energy Efficient Motors
Full-Load Efficiencies of NEMA Premium™ Efficient Motors
Effect of Voltage Variation on Motor Characteristics
Power Supply and Motor Voltages
Effect of Voltage Unbalance on Motor Performance
Starting Characteristics of Squirrel Cage Induction Motors
Allowable Starts and Starting Intervals

MOTOR DATA–MECHANICAL
Suffixes to NEMA Frames
NEMA Frame Assignments–Three-Phase Motors
NEMA Frame Dimensions–AC Machines
IEC Mounting Dimensions–Foot-Mounted AC and DC Machines
IEC Shaft Extension, Key And Keyseat Dimensions–Continuous Duty AC Motors (Inches)
NEMA Shaft Extension And Keyseat
Dimensions–Foot-Mounted DC Machines (Inches)
NEMA Frame Dimensions–Foot-Mounted DC Machines (Inches)
NEMA Frame Dimensions–AC Machines (mm)
IEC Mounting Dimensions–Foot-Mounted AC and DC Machines (mm)
IEC Shaft Extension, Key and Keyseat Dimensions–Continuous Duty AC Motors (mm)
NEMA Shaft Extension and Keyseat Dimensions–Foot-Mounted DC Machines (mm)
NEMA Frame Dimensions–Foot-Mounted DC Machines (mm)

MOTOR CONTROLS
Power Factor Improvement of Induction Motor Loads
Capacitor kVAR Rating for Power-Factor Improvement
Full-Load Currents–Motors
Maximum Locked-Rotor Currents–Three-Phase Motors
NEMA Code Letters for AC Motors
Starter Enclosures
NEMA Size Starters for Three-Phase Motors
NEMA Size Starters for Single-Phase Motors
Derating Factors for Conductors in a Conduit
Allowable Ampacities of Insulated Conductors
Motor Protection Devices–Maximum Rating or Setting

TRANSFORMERS
Full-Load Currents for Three-Phase Transformers
Full-Load Currents for Single-Phase Transformers
Transformer Connections

MISCELLANEOUS
Temperature Classification of Insulation Systems
Resistance Temperature Detectors.
Thermocouple Junction Types
Dimensions, Weight and Resistance: Solid Round Copper Wire (AWG and Metric)
Square Bare Copper Wire (AWG)
Insulation Resistance and Polarization Index Tests
Properties of Metals and Alloys

USEFUL FORMULAS AND CONVERSIONS
Temperature Correction of Winding Resistance
Temperature Correction of Insulation Resistance.
Formulas for Electric Motors and Electrical Circuits.
Motor Application Formulas
Centrifugal Application Formulas
Temperature Conversion Chart
Conversion Factors
Fractions of an Inch–Decimal and Metric Equivalents

Available Downloads

Getting the Most from Winding RTDs

Getting the Most from Winding RTDs

Winding RTDs are resistance-based temperature monitoring devices. Aside from just reporting winding temperature, here are some tips for maximizing the benefit of RTDs. Place six RTDs, spacing them uniformly around the core so there are two per phase. Provide a location map, numbering the RTDs, starting with the number 1 RTD in the 12:00 position. Number the RTDs clockwise facing the connection end.

Knowing where each RTD is located (which phase, as well as the physical location in the stator) provides some powerful diagnostic ability. Possible causes for deviation in temperature are:

  • Two RTDs reading high, and both in the same phase: Check for voltage / current unbalance; higher current in one phase causes higher temperature in that phase.
  • If the number of circuits is half the number of poles, circulating currents can occur. This situation can be exacerbated by uneven airgap which cause a further temperature increase. The corrective action, in this case, is to use the appropriate extra-long jumpers when connecting the winding.
  • Higher temperature indicated in adjacent RTDs may indicate obstructed ventilation. Some possible causes are clogged filters, missing soundproofing, displaced weather-stripping, poorly positioned air baffles, or a missing J-box cover.
  • Some manufacturers place all six RTDs across the 10:00 to 2:00 portion of the winding, to report more uniform temperatures. By distributing the RTDs symmetrically around the stator -- instead of just on the top -- the reported apparent temperatures often look alarming. Before returning the motor, let the end-user know where they were originally, and explain that the symmetrical placement will yield more realistic results.

Help With Installing Winding Resistance Temperature Detectors (RTDs)

Help With Installing Winding Resistance Temperature Detectors (RTDs)

When installing winding Resistance Temperature Detectors (RTDs), divide the number of stator slots by the number of RTDs to install (usually six) and mark the slots accordingly. For example, a 72-slot stator with six RTDs would position an RTD in every 12th slot. That results in two RTDs per phase. Be sure to number the RTDs and provide a map of their locations to aid the customer in interpreting temperature differences. For example, unbalanced voltage might result in higher temperature in two RTDs in the same phase, while obstructed ventilation is likely to cause higher temperature in two or three adjacent RTDs.

One anomaly is WPI or WPII (weather protected) enclosures, where the top hood is integral to airflow. Some manufacturers place all six RTDs across the top of the windings (from the 10:00 - 2:00 positions) so that all RTDs are within the area receiving better cooling. This is not deceptive; it’s just meant to avoid a customer asking questions about temperature differences. For repairers, it’s a talking point with your customer when rewinding such a motor. Do they want the RTDs evenly spaced, recognizing that they will see the differences in actual operating temperature? Or do they want them placed as the manufacturer did? Better to have that conversation first, rather than raise doubts after the motor returns to service.

Note that, depending on the coils/ group and pitch, an RTD might be between top and bottom coils of the same phase, or of different phases.

Identifying different types of temperature detectors

Identifying different types of temperature detectors

Anthony Sieracki 
Spina Electric Co.

Often during the rebuild and overhaul of a piece of electrical apparatus, we are faced with the challenge to identify the type of temperature detection devices that need to be replaced. The identification process should start at the beginning of the rebuild when the apparatus starts its way through the service center. Most major manufacturers identify the temperature detection device on a connection plate in the motor terminal box and many have a connection diagram indicating the type of device used. You can also refer to the manufacturer's catalog where they identify the type of temperature detector that has been used. Needless to say, it is usually too late to start identifying the temperature sensor after the winding is reclaimed and the device is now dust. Because that does happen, let's look at the styles and types of winding temperature detectors. Types of temperature detectors discussed include:

  • Resistance Temperature Detectors (RTDs)
  • Thermocouples
  • Thermistors
  • Thermostats

Available Downloads

Increasing Motor Reliability

Increasing Motor Reliability

Regularly Checking the Operating Temperature of Critical Motors Will Help Extend Their Life and Prevent Costly, Unexpected Shutdowns

Tom Bishop, P.E.
EASA Senior Technical Support Specialist

It’s a striking fact that operating a three-phase induction motor at just 10°C above its rated temperature can shorten its life by half. Whether your facility has thousands of motors or just a few, regularly checking the operating temperature of critical motors will help extend their life and prevent costly, unexpected shutdowns. This article will show you how to go about it.

READ THE FULL ARTICLE

Motor Winding Temperature and Detectors to Measure It

Motor Winding Temperature and Detectors to Measure It

This presentation begins with an overview of ambient, winding temperature rise, and winding temperature. It also covers factors for motor temperature rise limits such as motor size (medium or large), insulation class rating, service factor and the enclosure. The final part of the presentation addresses detectors for measuring winding temperature, namely thermostats, resistance temperature detectors (RTDs), thermocouples and thermistors.

Target audience: This presentation is most useful for service center winders, engineers, supervisors and managers. The content will be beneficial for beginners through highly-experienced persons.

Principles of Medium & Large AC Motors, 1st Edition - IEC

Principles of Medium & Large AC Motors, 1st Edition - IEC

This version of Principles of Medium & Large AC Motors manual is now available to address applicable IEC standards and practices. This 360-page manual was developed by industry experts in Europe along with EASA's engineering team. (The "original" version of this book based on NEMA standards remains available as a separate document.)

This manual includes drawings, photos and extensive text and documentation on AC motors, including how they work, information on enclosures, construction on components and applications. Many of the principles included apply to all AC motors, especially those with accessories that are associated with larger machines in the past (such as encoders, RTDs, thermostats, space heaters and vibration sensors).

While the manual covers horizontal and vertical squirrel-cage induction motors in the 37 to 3,700 kW (300 to 5,000 hp) range, low- and medium-voltage, most of the principles covered apply to other sizes as well. 

This valuable instructional/resource manual is available in printed and downloadable versions, and focuses primarily on IEC motors.

Sections in the manual include:
(Download the PDF below for the complete Tables of Contents)

  • Motor nomenclature & definitions
  • Motor enclosures
  • Typical motor applications
  • Safety & handling considerations
  • Basic motor theory
  • Motor standards
  • Stators
  • Squirrel cage rotors
  • Shafts
  • Bearings & lubrication
  • Motor accessories & terminal boxes
  • Test & inspection procedures
  • Motor alignment, vibration & noise
  • Storage procedures
  • Synchronous machines

BUY A COPY FOR YOUR OFFICE

PRINTED BOOK DOWNLOADABLE PDF

This book is also available focusing on NEMA Standards — in both English and Español.

NEMA - English NEMA - Español

Available Downloads

Sensores de Temperatura para Bobinados y Rodamientos

Sensores de Temperatura para Bobinados y Rodamientos

En Español

Jasper Electric Motors, Inc.Carlos Ramirez
Especialista de Soporte Técnico de EASA

Para monitorear la temperatura de los bobinados y en los rodamientos se pueden usar diferentes tipos de dispositivos. La correcta identificación de los mismos es importante para determinar el tipo de  sensor en casos en los que el dispositivo es desconocido o para escoger el dispositivo correcto para una determinada aplicación.

El webinario incluye:

  • RTDs
  • Termopares, termostatos y termistores
  • Determinar el tipo de sensor desconocido y pruebas
  • Controladores

Este webinario es útil para bobinadores, mecánicos, supervisores y técnicos de pruebas.

Winding and Bearing Temperature Sensors

Carlos Ramirez
EASA Technical Support Specialist

Different types of devices can be used to monitor winding and bearing temperature. Correctly identifying detector types is important to determine the type of sensor in cases where the temperature detector is unknown or for choosing the correct device to fit an application.

This recording covers:

  • RTDs
  • Thermocouples, thermostats, and thermistors
  • Determining unknown type of detector and testing
  • Controllers

This recording is intended for winders, mechanics, supervisors, and testing technicians.

Available Downloads

Temperature detectors: Choosing the correct device to fit the application

Temperature detectors: Choosing the correct device to fit the application

Tom Bishop, P.E. 
EASA Technical Support Specialist 

When we mention temperature detectors for motors we usually think of winding temperature detectors. However, temperature detectors can also be used to monitor bearings and airflow. In this article we will describe the more common types of tempera­ture detectors and how they can be applied to windings, bearings and to check ventilation (airflow). 

We will begin by describing the different types of temperature detectors most commonly used in motors and generators. For simplicity we will use the term “motors” to mean both motors and generators. Although our focus is on temperature detectors for motors and generators, the detectors may also be found in transformers and other equipment. These are resistance temperature detectors (RTDs), thermocouples, thermostats, and thermistors. 

Available Downloads

Thermistors: What they are and how they work

Thermistors: What they are and how they work

Tom Bishop, P.E.
EASA Senior Technical Support Specialist

What are thermistors?

Thermistors, derived from the term thermally sensitive resistors, are a very accurate and cost effective method for measuring temperature. Thermistors are usually two-terminal semiconductor devices made from semi-conductor materials that have an electrical resistance that varies non-linearly with temperature (see Figure 1). Some materials provide better stability while others have higher resistance ranges and are fabricated into smaller thermistors.  Each specific thermistor has its own unique resistance versus temperature characteristic. 

Available Downloads

Winding & Bearing Temperature Sensing Devices

Winding & Bearing Temperature Sensing Devices

This presentation addresses the topic of a various temperature sensing devices including RTDs, thermostats, thermocouples and thermistors. The advantages of each and the proper application will be covered.

Target audience: This presentation will be most useful for service center sales personnel, engineers, supervisors and managers. The content will be beneficial for moderate through highly-experienced persons.