Avoiding high no-load amps on rewound motors

  • February 2004
  • Number of views: 3509
  • Article rating: 5.0

Tom Bishop, P.E. 
EASA Technical Support Specialist
 
Have you ever had to deal with a rewound motor that had high no-load amps? That is almost a rhetori­cal question as most of us have experienced this situation. The focus of this article will be on steps to take before rewinding in order to avoid the condition of high amps after the rewind. 

Steps that should be performed on every AC stator rewind: 

  1. Inspect the stator bore and rotor outside diameter for evidence of machining or damage. 
  2. Record the original winding data exactly as found. 
  3. Test the stator core before winding removal. 
  4. Verify the winding data. 
  5. Test the stator core after winding removal and cleaning. Applying these five steps will help avoid the vast majority of situations where a rewound motor will exhibit high no-load current. If these steps were not all followed and a motor has high no-load current, if possible, perform any steps above that were omitted. 

LOGIN TO VIEW AND DOWNLOAD THE ARTICLE



Print


PREVIOUS ITEM
Comments are only visible to subscribers.

Getting The Most From Your Electric Motors

Getting The Most From Your Electric Motors - coverThis 40-page booklet provides great advice for obtaining the longest, most efficient and cost-effective operation from general and definite purpose electric motors.

This booklet covers topics such as:

  • Installation, startup and baseline information
  • Operational monitoring and maintenance
  • Motor and baseline installation data
  • How to read a motor nameplate
  • Motor storage recommendations

LEARN MORE AND DOWNLOAD MÁS INFORMACIÓN Y DESCARGAR BUY PRINTED COPIES

READ MORE ABOUT THE FEATURES AND BENEFITS

EASA/AEMT Rewind Study

EASA Rewind Study cover

The Effect of Repair/Rewinding on Premium Efficiency/IE3 Motors
Tests prove Premium Efficiency/IE3 Motors can be rewound without degrading efficiency.

DOWNLOAD THE FULL RESULTS

ANSI/EASA AR100-2020

ANSI/EASA AR100-2015 cover

Recommended Practice for the Repair of Rotating Electrical Apparatus
This is a must-have guide to the repair of rotating electrical machines. Its purpose is to establish recommended practices in each step of the rotating electrical apparatus rewinding and rebuilding processes.

DOWNLOAD - ENGLISH

DESCARGAR - ESPAÑOL

EASA Technical Manual

EASA Technical Manual cover

Revised September 2022
The EASA Technical Manual is the association's definitive and most complete publication. It's available FREE to members in an online format. Members can also download PDFs of the entire manual or individual sections.

VIEW & DOWNLOAD